Disposable Trocar
video

Disposable Trocar

REF.:KED01.004
Size:12.5*95mm
Disposable endoscopic trocars are intended to establish a port of entry for endoscopic instruments used during laparoscopic procedures.
Send Inquiry
Chat Now
Product Introduction

Disposable Bladeless Trocar

Disposable Bladeless Crown Trocar Set 12.5*95mm

Disposable bladeless trocar is a high quality, European designed and manufactured product with unique features, full range of models and sizes never before seen at this price point.

Trocars are made from the highest standard of materials available.

The main material used in trocars is Makrolon.

MOQ:1sets

Samples time:within 7 days

Lead time:within 25 days

Code

Description

Size

MOQ

KED01.002

Disposable Bladeless Crown Trocar Set

5.5*95mm

1

KED01.003

Disposable Bladeless Crown Trocar Set

10.5*95mm

1

KED01.004

Disposable Bladeless Crown Trocar Set

12.5*95mm

1

Disposable trocar set(Bladeless), Reducer cap trocar, Arthroscopy trocar

1.The trocar obturator and cannula may be packaged unassembled. Assemble the trocar by inserting the obturator into the trocar cannula until they match together (the protrusion designed on the obturator should be inserted into groove of the top house).

2.Select and follow a suitable endoscopic and/or laparoscopic protocol.

3. If the trocar is packaged with the stopcock in its open state. To prevent exsufflation during insertion, close the valve prior to use.

4.Establish the primary puncture site and insufflate the operative cavity using recommended procedures.

5.Make a small incision where instrument will be introduced.

6.Ensure there is no blood vessel or grume existing in incision area. Insert the obturator and cannula according to the texture level of tissue through the incision by applying continuous controlled downward pressure until the body cavity has been completely penetrated.

7.To insufflate, attach a gas line to the trocar port and open its valve.

8. Remove the obturator and insert appropriately sized instruments.

9. When retrieving a tissue sample through a cannula with a top housing, detach the top housing and slide up the instrument shaft until the specimen has been removed.(when closing the top housing again, ensure the arrow on the top housing aims at the vent valve and then screw rightward to close the top housing)

10. For the trocars with reducer cap, put the reducer cap back onto the top housing when inserting 5mm instruments.

11.At the end of the procedure, leave the laparoscope in place during exsufflation and removal of the trocar cannula. Exteriorization of the cavity contents can occur if the laparoscope is first pulled from the cannula.Remove the cannula, and suture the incision site.


--------------------------------------------------------------------------------------------------------------------

Con.:Jane Dong

Email: jane.dong@tlkanger.cn

Mob./WhatApp/Wechat:+86 15057102103

Tonglu Kanger Medical Instrument Co.,Ltd _01

Tonglu Kanger Medical Instrument Co.,Ltd _02

Tonglu Kanger Medical Instrument Co.,Ltd _03

Hot Tags: Disposable Trocar, China, suppliers, manufacturers, factory, wholesale, cheap, price, in stock, buy discount

Send Inquiry

whatsapp

Phone

E-mail

Inquiry