Disposable Trocar
Size:12.5*95mm
Disposable endoscopic trocars are intended to establish a port of entry for endoscopic instruments used during laparoscopic procedures.
Disposable Bladeless Trocar
Disposable Bladeless Crown Trocar Set 12.5*95mm
Disposable bladeless trocar is a high quality, European designed and manufactured product with unique features, full range of models and sizes never before seen at this price point.
Trocars are made from the highest standard of materials available.
The main material used in trocars is Makrolon.
MOQ:1sets
Samples time:within 7 days
Lead time:within 25 days
Code | Description | Size | MOQ |
KED01.002 | Disposable Bladeless Crown Trocar Set | 5.5*95mm | 1 |
KED01.003 | Disposable Bladeless Crown Trocar Set | 10.5*95mm | 1 |
KED01.004 | Disposable Bladeless Crown Trocar Set | 12.5*95mm | 1 |
Disposable trocar set(Bladeless), Reducer cap trocar, Arthroscopy trocar
1.The trocar obturator and cannula may be packaged unassembled. Assemble the trocar by inserting the obturator into the trocar cannula until they match together (the protrusion designed on the obturator should be inserted into groove of the top house).
2.Select and follow a suitable endoscopic and/or laparoscopic protocol.
3. If the trocar is packaged with the stopcock in its open state. To prevent exsufflation during insertion, close the valve prior to use.
4.Establish the primary puncture site and insufflate the operative cavity using recommended procedures.
5.Make a small incision where instrument will be introduced.
6.Ensure there is no blood vessel or grume existing in incision area. Insert the obturator and cannula according to the texture level of tissue through the incision by applying continuous controlled downward pressure until the body cavity has been completely penetrated.
7.To insufflate, attach a gas line to the trocar port and open its valve.
8. Remove the obturator and insert appropriately sized instruments.
9. When retrieving a tissue sample through a cannula with a top housing, detach the top housing and slide up the instrument shaft until the specimen has been removed.(when closing the top housing again, ensure the arrow on the top housing aims at the vent valve and then screw rightward to close the top housing)
10. For the trocars with reducer cap, put the reducer cap back onto the top housing when inserting 5mm instruments.
11.At the end of the procedure, leave the laparoscope in place during exsufflation and removal of the trocar cannula. Exteriorization of the cavity contents can occur if the laparoscope is first pulled from the cannula.Remove the cannula, and suture the incision site.
--------------------------------------------------------------------------------------------------------------------
Con.:Jane Dong
Email: jane.dong@tlkanger.cn
Mob./WhatApp/Wechat:+86 15057102103
Hot Tags: Disposable Trocar, China, suppliers, manufacturers, factory, wholesale, cheap, price, in stock, buy discount