Nasal Power Drill
video

Nasal Power Drill

Code:BD-7
Send Inquiry
Chat Now
Product Introduction

Nasal Power Drill

BD-7 Nasal Power Drill
Item No.NameSpecification
B5001Control box
B3007HandpieceStraight
B3005.1Blade4mm Oblique with tooth
B3005.2Blade4mm Oblique without tooth
B3005.3Blade4mm Inside&outside with tooth
B3005.4Blade4mm Ball shape
B5002Footswitch
B3003Irrigation head
Options

B3005.5Curved Blade4.5mm 20° Oblique with tooth on obverse side
B3005.6Curved Blade4.5mm 20° Oblique with tooth on inverse side
B3005.7Curved Blade4.5mm 40° Oblique with tooth on obverse side
B3005.8Curved Blade4.5mm 40° Oblique with tooth on inverse side
B3005.9Curved Blade4.5mm 60° Oblique with tooth on obverse side
B3005.10Curved Blade4.5mm 60° Oblique with tooth on inverse side
B3005.11Curved Blade4.5mm 75° tooth on obverse side
B3005.12Curved Blade4.5mm 75°   tooth on inverse side
B3005.13Curved Blade4mm 20° Oblique with tooth on obverse side
B3005.14Curved Blade4mm 20° Oblique with tooth on inverse side
B3005.23Blade4.5mm Oblique with tooth
B3005.24Blade4.5mm Oblique without tooth
B3005.25Blade4.5mm Inside&outside with tooth

Nasal power drill used for the functional sinoscopy operation.

The power drill is consisting of main console, hand piece, blades and pedal.

Product name

Item

Model BD nasal power drill

Power supply

220V±22V、50HZ±1HZ

Rotate speed

1 2750t/min——3200t/min

2 1750t/min——2200t/min

3 1250t/min——1600t/min

4 750t/min——1000t/min

Output power

Maximum no more than 25W

Rotating torque

The torque no less then 0.02N.m

Clean and the sterilizing the blade

1. Firstly use the no salt water( pure water or distill water) clean the blades totally;

2. The cleaned blades should be dried by pressed air or by the clean cotton cloth or tissue. (can not use the fiber and normal cloth)

3. Put the cleaned blades to the sterilized lace or the pan for preparation.

4. Can use the EO (ethylene oxygen) suffocating, Cobalt 60 Ray, dry and heat serializing or the autoclave.

5. When emergency, also can use the no salt and cankerous sterilized liquid to marinate, then dry it. Do not be over on night, otherwise will influence the lifetime.

6. Forbidden the flame ( harm to the blade rigidity) and forbidden to use aquae hydrogenii dioxide and the other canker liquid.

------------------------------------------------------------------------------------------------------------------

Contacts:Jane Dong

Email: jane.dong@tlkanger.cn

Mob./WhatsApp/Wechat:+86 15057102103

Tonglu Kanger Medical Instrument Co.,Ltd _01

Tonglu Kanger Medical Instrument Co.,Ltd _02

Tonglu Kanger Medical Instrument Co.,Ltd _03

Hot Tags: nasal power drill, China, suppliers, manufacturers, factory, wholesale, cheap, price, in stock, buy discount, laparoscopy training box laparoscopic trainer set, Laparoscopic Endo Trainer Training Practice Instruments, Laparoscopic Trainer Box Laparoscopic Trainer Simulator, Laparoscopic Trainer Simulator, Laparoscopic Simulation Surgical Science, Laparoscopic Surgical Training Instruments Set

Send Inquiry

whatsapp

Phone

E-mail

Inquiry