Nasal Power Drill
| BD-7 Nasal Power Drill | ||
| Item No. | Name | Specification |
| B5001 | Control box | |
| B3007 | Handpiece | Straight |
| B3005.1 | Blade | 4mm Oblique with tooth |
| B3005.2 | Blade | 4mm Oblique without tooth |
| B3005.3 | Blade | 4mm Inside&outside with tooth |
| B3005.4 | Blade | 4mm Ball shape |
| B5002 | Footswitch | |
| B3003 | Irrigation head | |
| Options | ||
| B3005.5 | Curved Blade | 4.5mm 20° Oblique with tooth on obverse side |
| B3005.6 | Curved Blade | 4.5mm 20° Oblique with tooth on inverse side |
| B3005.7 | Curved Blade | 4.5mm 40° Oblique with tooth on obverse side |
| B3005.8 | Curved Blade | 4.5mm 40° Oblique with tooth on inverse side |
| B3005.9 | Curved Blade | 4.5mm 60° Oblique with tooth on obverse side |
| B3005.10 | Curved Blade | 4.5mm 60° Oblique with tooth on inverse side |
| B3005.11 | Curved Blade | 4.5mm 75° tooth on obverse side |
| B3005.12 | Curved Blade | 4.5mm 75° tooth on inverse side |
| B3005.13 | Curved Blade | 4mm 20° Oblique with tooth on obverse side |
| B3005.14 | Curved Blade | 4mm 20° Oblique with tooth on inverse side |
| B3005.23 | Blade | 4.5mm Oblique with tooth |
| B3005.24 | Blade | 4.5mm Oblique without tooth |
| B3005.25 | Blade | 4.5mm Inside&outside with tooth |
Nasal power drill used for the functional sinoscopy operation.
The power drill is consisting of main console, hand piece, blades and pedal.
Product name Item | Model BD nasal power drill |
Power supply | 220V±22V、50HZ±1HZ |
Rotate speed | 1 2750t/min——3200t/min 2 1750t/min——2200t/min 3 1250t/min——1600t/min 4 750t/min——1000t/min |
Output power | Maximum no more than 25W |
Rotating torque | The torque no less then 0.02N.m |
Clean and the sterilizing the blade
1. Firstly use the no salt water( pure water or distill water) clean the blades totally;
2. The cleaned blades should be dried by pressed air or by the clean cotton cloth or tissue. (can not use the fiber and normal cloth)
3. Put the cleaned blades to the sterilized lace or the pan for preparation.
4. Can use the EO (ethylene oxygen) suffocating, Cobalt 60 Ray, dry and heat serializing or the autoclave.
5. When emergency, also can use the no salt and cankerous sterilized liquid to marinate, then dry it. Do not be over on night, otherwise will influence the lifetime.
6. Forbidden the flame ( harm to the blade rigidity) and forbidden to use aquae hydrogenii dioxide and the other canker liquid.
------------------------------------------------------------------------------------------------------------------
Contacts:Jane Dong
Email: jane.dong@tlkanger.cn
Mob./WhatsApp/Wechat:+86 15057102103



Hot Tags: nasal power drill, China, suppliers, manufacturers, factory, wholesale, cheap, price, in stock, buy discount, laparoscopy training box laparoscopic trainer set, Laparoscopic Endo Trainer Training Practice Instruments, Laparoscopic Trainer Box Laparoscopic Trainer Simulator, Laparoscopic Trainer Simulator, Laparoscopic Simulation Surgical Science, Laparoscopic Surgical Training Instruments Set